UMIYA SUCTION CATH
UMIYA SUCTION CATH
Medkart reliability icon

Authentic Product

India's Leading Generic Pharmacy

India's Leading Generic Pharmacy

Secure Payment

Secure Payment

UMIYA SUCTION CATH

Share icon

UMIYA SUCTION CATH

By SURGICAL

MRP

80

₹64

20 % OFF


Location icon

Check Delivery

or
Arrives in:

--


Product DetailsArrow

About UMIYA SUCTION CATH

  • The UMIYA Suction Cath is a sterile, single-use medical device designed for effective and safe removal of secretions from the respiratory tract. Manufactured from non-toxic, medical-grade PVC, it offers optimal flexibility and minimizes the risk of trauma to the delicate airway tissues. Its smooth surface facilitates easy insertion and maneuverability, enhancing patient comfort and reducing potential complications.
  • The catheter features a precisely crafted distal tip with strategically placed aspiration eyes. These eyes are designed to maximize suction efficiency while minimizing the risk of tissue aspiration. The proximal end is fitted with a universal connector, ensuring compatibility with standard suction equipment commonly found in hospitals and clinics. Clear depth markings along the catheter's length enable precise positioning and control during the suctioning procedure, vital for patient safety and effective secretion removal.
  • Available in a range of sizes (French gauges), the UMIYA Suction Cath caters to diverse patient needs, from neonates to adults. Each catheter is individually packaged to maintain sterility and prevent cross-contamination. The clear packaging allows for easy visual inspection of the catheter before use. UMIYA Suction Cath is an indispensable tool for maintaining airway patency in various clinical settings, including intensive care units, operating rooms, and emergency departments, and for patients recovering at home.
  • Proper technique and training are essential when using the UMIYA Suction Cath. Healthcare professionals should always adhere to established protocols and guidelines for airway management. Routine suctioning should be avoided, and the procedure should be performed only when clinically indicated, such as in cases of excessive secretions, airway obstruction, or impaired cough reflex. Regular monitoring of the patient's respiratory status, including oxygen saturation and breath sounds, is crucial during and after suctioning.

Uses of UMIYA SUCTION CATH

  • Removal of secretions from the respiratory tract
  • Aspiration of fluids from the mouth, nose, and trachea
  • Maintaining a clear airway
  • Assisting patients with breathing difficulties
  • Post-operative removal of secretions
  • Managing secretions in ventilated patients
  • Clearing secretions in newborns
  • Removal of secretions in patients with pneumonia
  • Unblocking obstructed airways
  • Obtaining diagnostic samples

How UMIYA SUCTION CATH Works

  • The UMIYA Suction Cath, a critical tool in airway management, functions through a simple yet effective mechanism based on the principles of negative pressure and fluid dynamics. Its primary purpose is to clear secretions, fluids, or foreign materials from the patient's airway, ensuring unobstructed breathing and preventing complications such as aspiration pneumonia or respiratory distress.
  • The catheter, typically made of flexible, medical-grade PVC or silicone, is carefully inserted into the patient's airway – either through the nose (nasotracheal suctioning), mouth (orotracheal suctioning), or an existing endotracheal or tracheostomy tube. The insertion process is guided by anatomical landmarks and clinical assessment to ensure accurate placement and minimize trauma to the delicate airway tissues.
  • Once the catheter is positioned correctly, the proximal end, which remains outside the patient, is connected to a suction source. This source generates a vacuum, creating negative pressure within the catheter lumen. As the negative pressure is applied, fluids and debris within the airway are drawn into the catheter through small openings or ports located near the distal tip. The suction force, carefully regulated to avoid injury to the mucosal lining of the airway, effectively aspirates the unwanted materials.
  • The flexible nature of the UMIYA Suction Cath allows it to navigate the complex anatomy of the respiratory tract, reaching areas that are difficult to access with rigid instruments. The smooth surface of the catheter minimizes friction and reduces the risk of tissue damage during insertion and removal. Different sizes and types of suction catheters are available to accommodate various patient populations, from neonates to adults, and to suit specific clinical scenarios. Some catheters also incorporate features such as a control valve to regulate suction pressure or a directional tip to facilitate targeted aspiration.
  • The aspirated fluids and debris are collected in a collection canister attached to the suction source, allowing for easy disposal and, if necessary, laboratory analysis. Proper technique and adherence to infection control protocols are essential during suctioning to prevent the spread of pathogens and ensure patient safety. This includes using sterile catheters, wearing appropriate personal protective equipment, and limiting the duration of suctioning to minimize hypoxia and airway trauma. Regular monitoring of the patient's vital signs and respiratory status is also crucial throughout the procedure.
  • In summary, the UMIYA Suction Cath works by creating a localized vacuum within the airway to aspirate secretions and debris, thereby maintaining a clear airway and supporting optimal respiratory function. Its design, material composition, and proper usage are all critical factors in ensuring its effectiveness and minimizing potential complications.

Side Effects of UMIYA SUCTION CATHArrow

While UMIYA SUCTION CATH is designed for safe and effective suctioning, potential side effects may include: * **Trauma to the airway:** This could involve injury to the nasal passages, throat, or trachea, leading to bleeding or discomfort. * **Infection:** Introduction of bacteria into the airway is possible, potentially causing a respiratory infection. * **Hypoxia:** Prolonged suctioning can reduce oxygen levels in the blood. * **Atelectasis:** Excessive suctioning force can lead to lung collapse. * **Vagal stimulation:** Suctioning can stimulate the vagus nerve, causing a drop in heart rate (bradycardia). * **Gagging or vomiting:** Suctioning may trigger the gag reflex, leading to vomiting or retching. * **Bronchospasm:** Irritation from the catheter can cause the airway muscles to tighten, leading to difficulty breathing. * **Perforation:** (Rare) Accidental puncture of the airway. * **Discomfort or pain:** Suctioning can be an uncomfortable procedure, especially for sensitive individuals.

Safety Advice for UMIYA SUCTION CATHArrow

default alt

Allergies

Allergies

Do not use UMIYA SUCTION CATH if you are allergic to it.

Dosage of UMIYA SUCTION CATHArrow

  • The appropriate size and type of UMIYA SUCTION CATH should be selected based on the patient's age, size, and specific clinical needs. It is crucial to use the correct size to avoid trauma to the respiratory tract. For neonates and infants, smaller sizes (e.g., 6Fr or 8Fr) are generally preferred, while larger sizes (e.g., 10Fr or 12Fr) may be suitable for older children and adults. Verify the patency of the suction catheter before each use. To do so, gently aspirate a small amount of sterile saline through the catheter. This ensures that the suction catheter is free from obstructions and will function effectively during suctioning. Lubricate the suction catheter with sterile saline or water-soluble lubricant prior to insertion. Lubrication minimizes friction and reduces the risk of mucosal damage. Always follow sterile techniques during suctioning to prevent infection. Use sterile gloves and maintain a sterile field. Insert the suction catheter gently and carefully into the trachea or nasopharynx, avoiding excessive force. The depth of insertion should be guided by anatomical landmarks and clinical judgment.
  • The duration of suctioning should be limited to 5-10 seconds per pass to prevent hypoxia and airway trauma. Monitor the patient's oxygen saturation and heart rate during suctioning. Apply intermittent suction while withdrawing the catheter in a rotating motion. This technique helps to remove secretions from all sides of the airway and minimizes mucosal damage. Adjust the suction pressure based on the patient's age and clinical condition. Excessive suction pressure can cause trauma to the airway. For neonates and infants, lower suction pressures (e.g., 60-80 mmHg) are recommended, while higher pressures (e.g., 80-120 mmHg) may be appropriate for older children and adults. After each suctioning pass, assess the patient's respiratory status and allow them to recover before repeating the procedure. Hyperoxygenate the patient before and after suctioning to prevent hypoxia. Dispose of the suction catheter immediately after use in a designated biohazard container. Never reuse suction catheters.
  • Suctioning should be performed only when clinically indicated, such as when the patient has excessive secretions, difficulty clearing their airway, or signs of respiratory distress. Regular assessment of the patient's respiratory status is essential to determine the need for suctioning. Document the procedure, including the date, time, catheter size, suction pressure, amount and consistency of secretions, and the patient's response. Always be aware of potential complications, such as hypoxia, bradycardia, airway trauma, and infection. Have emergency equipment readily available in case of adverse events. Proper training and competency are essential for healthcare providers who perform suctioning. Ensure that all personnel are familiar with the correct techniques and potential complications.
  • Take 'UMIYA SUCTION CATH' only as per the prescription by your physician only

What if I miss my dose of UMIYA SUCTION CATH?Arrow

  • UMIYA Suction Catheter is a medical device and not a medication. Therefore, the concept of a 'missed dose' does not apply. Use as directed by your healthcare provider.

How to store UMIYA SUCTION CATH?Arrow

  • Keep UMIYA SUCTION CATH away from the reach of children and pets.
  • Store UMIYA SUCTION CATH at room temperature.

Benefits of UMIYA SUCTION CATHArrow

  • Umiya Suction Catheters are meticulously designed to ensure effective and efficient removal of secretions and fluids from the respiratory tract. This helps maintain a clear airway, which is crucial for patients who are unable to clear their own airways due to illness, surgery, or other medical conditions. A clear airway reduces the risk of aspiration and improves oxygenation.
  • The soft, flexible material of Umiya Suction Catheters minimizes trauma to the delicate tissues of the respiratory tract during insertion and suctioning. This is particularly important for patients who require frequent suctioning, as repeated trauma can lead to inflammation, bleeding, and discomfort. The smooth surface of the catheter further reduces friction and irritation.
  • Umiya Suction Catheters are available in a variety of sizes to accommodate the diverse needs of patients, from neonates to adults. This ensures that the appropriate size catheter can be selected for each patient, optimizing suctioning effectiveness and minimizing the risk of complications. The size range allows healthcare professionals to tailor the suctioning procedure to the individual patient's anatomy and condition.
  • The clear construction of Umiya Suction Catheters allows for easy visualization of the aspirated fluid, enabling healthcare professionals to monitor the color, consistency, and volume of secretions. This visual feedback can provide valuable information about the patient's respiratory status and help guide treatment decisions. For example, the presence of blood or thick mucus can indicate potential problems that require further investigation.
  • Umiya Suction Catheters are designed for single-use, which eliminates the risk of cross-contamination between patients. This is a critical infection control measure that helps prevent the spread of healthcare-associated infections (HAIs). Single-use catheters also save time and resources by eliminating the need for cleaning and sterilization.
  • The ergonomic design of Umiya Suction Catheters facilitates easy and comfortable handling for healthcare professionals. The smooth, rounded tip of the catheter ensures atraumatic insertion, while the clearly marked depth markings allow for precise placement. The suction control port is designed for easy thumb control, allowing for intermittent suctioning as needed.
  • Umiya Suction Catheters are compatible with standard suction equipment, making them easy to integrate into existing clinical workflows. They can be used with a variety of suction machines and collection canisters, providing flexibility and convenience for healthcare professionals. The universal connector ensures a secure and leak-proof connection.
  • The radiopaque line incorporated into Umiya Suction Catheters allows for visualization under X-ray, confirming proper placement of the catheter. This is particularly useful in situations where direct visualization is difficult or impossible. The radiopaque line helps to ensure that the catheter is positioned correctly before suctioning is initiated, minimizing the risk of complications.
  • Umiya Suction Catheters are manufactured from high-quality, medical-grade materials that are biocompatible and latex-free. This reduces the risk of allergic reactions and ensures patient safety. The materials are also resistant to degradation from prolonged exposure to bodily fluids.
  • Using Umiya Suction Catheters regularly helps prevent complications associated with retained secretions, such as pneumonia and atelectasis. By maintaining a clear airway, these catheters support optimal respiratory function and improve patient outcomes. This is especially important for patients who are at high risk for respiratory complications, such as those with chronic lung disease or neuromuscular disorders.

How to use UMIYA SUCTION CATHArrow

  • Before initiating suctioning with the UMIYA SUCTION CATH, meticulously assess the patient's respiratory status. This includes evaluating their oxygen saturation levels, respiratory rate, and the presence of any visible secretions. Ensure you have the appropriate size of suction catheter readily available, typically ranging from 6Fr to 16Fr, based on the patient's age and the viscosity of secretions anticipated. Also, gather all necessary equipment, including a suction machine, sterile saline solution, sterile gloves, and personal protective equipment (PPE).
  • Don sterile gloves to maintain asepsis throughout the procedure. Gently insert the UMIYA SUCTION CATH into the patient's airway, typically through the nose or mouth. Avoid applying suction during insertion to minimize trauma to the delicate mucous membranes. Advance the catheter to the desired depth, usually determined by the anatomical landmarks or pre-measured distance, ensuring not to force the catheter if resistance is encountered. For endotracheal suctioning, advance the catheter until resistance is met at the carina, then retract slightly before initiating suction.
  • Apply intermittent suction by occluding the suction control port, while gently rotating and withdrawing the catheter. Limit each suctioning pass to a maximum of 10-15 seconds to prevent hypoxemia and airway trauma. Monitor the patient's oxygen saturation and heart rate closely during suctioning. If a significant drop in oxygen saturation or bradycardia occurs, immediately stop suctioning and administer supplemental oxygen. Following each suctioning pass, flush the catheter with sterile saline solution to clear any accumulated secretions and maintain patency.
  • Allow the patient to rest and recover between suctioning passes. Repeat the suctioning procedure as needed, based on the patient's clinical condition and the presence of secretions. Continuously assess the effectiveness of suctioning by monitoring the clearance of secretions and improvements in the patient's respiratory status. Discard the used UMIYA SUCTION CATH and suction collection container according to established hospital protocols for biohazardous waste disposal. Document the procedure, including the date, time, catheter size, amount and characteristics of secretions, and the patient's response to suctioning.

Quick Tips for UMIYA SUCTION CATHArrow

  • <b>Prior to Use:</b> Always inspect the UMIYA Suction Cath for any signs of damage or blockages before each use. Ensure the packaging is intact and the catheter is sterile to prevent infections. Using a damaged or non-sterile catheter can lead to serious complications.
  • <b>Proper Size Selection:</b> Choose the correct catheter size based on the patient's age, size, and the viscosity of secretions. Using a catheter that is too large can cause trauma to the airway, while one that is too small may not effectively clear secretions. Consult with a healthcare professional for guidance on appropriate sizing.
  • <b>Lubrication is Key:</b> Lubricate the UMIYA Suction Cath with sterile saline or water-soluble lubricant before insertion. This minimizes friction and reduces the risk of injury to the delicate tissues of the respiratory tract. Avoid using oil-based lubricants, as they can be harmful to the lungs.
  • <b>Gentle Insertion Technique:</b> Insert the UMIYA Suction Cath gently and with controlled movements. Avoid forcing the catheter, as this can cause trauma, bleeding, or perforation. Advance the catheter only as far as necessary to reach the secretions.
  • <b>Intermittent Suctioning:</b> Apply suction intermittently while withdrawing the catheter, using a rotating motion. Continuous suctioning can cause damage to the airway lining. Limit suctioning time to 10-15 seconds to prevent hypoxia. Monitor the patient's oxygen saturation levels during and after suctioning.
  • <b>Maintain Aseptic Technique:</b> Strictly adhere to aseptic techniques throughout the suctioning procedure to minimize the risk of infection. Use sterile gloves, and a sterile suction catheter. Clean the insertion site with an antiseptic solution if necessary.
  • <b>Monitor Patient Response:</b> Closely monitor the patient's vital signs, including heart rate, respiratory rate, and oxygen saturation, during and after suctioning. Discontinue the procedure if the patient exhibits signs of distress, such as bradycardia, desaturation, or coughing.
  • <b>Post-Suctioning Care:</b> After suctioning, encourage the patient to cough and deep breathe to help clear any remaining secretions. Assess the patient's respiratory status and provide supplemental oxygen if needed. Document the procedure, including the amount and consistency of secretions obtained, and the patient's response.

Food Interactions with UMIYA SUCTION CATHArrow

  • UMIYA SUCTION CATH is a medical device and does not interact with food. It is used for removing secretions from the airway and its functionality is not affected by food intake. Follow your healthcare provider's instructions for proper use.

FAQs

What is UMIYA Suction Cath used for?Arrow

UMIYA Suction Cath is used to remove fluids, such as mucus or saliva, from the respiratory tract to facilitate easier breathing.

How should I store UMIYA Suction Cath?Arrow

Store UMIYA Suction Cath in a clean, dry place away from direct sunlight and heat. Ensure the package integrity before use.

What should I consider before using UMIYA Suction Cath?Arrow

Before use, ensure you have the correct catheter size and are familiar with the proper technique. Consult a healthcare professional if unsure.

Is UMIYA Suction Cath reusable?Arrow

No, UMIYA Suction Cath is for single-use only. Reusing it can lead to infection.

What are the potential side effects of UMIYA Suction Cath?Arrow

Potential side effects may include mild coughing, sore throat, or difficulty breathing. Seek medical attention if symptoms persist.

How to choose the proper size for UMIYA Suction Cath?Arrow

The proper size selection depends on the patient's age, size, and viscosity of secretions. It is best to consult with your healthcare provider.

Can I use UMIYA Suction Cath at home?Arrow

UMIYA Suction Cath can be used at home, but only after proper training and guidance from a healthcare professional.

What precautions should I take while using UMIYA Suction Cath?Arrow

Precautions include maintaining proper hygiene, using a sterile technique, and avoiding the use of too much force while suctioning.

Is UMIYA Suction Cath latex-free?Arrow

Check the product packaging or manufacturer's specifications to verify the latex content of the UMIYA Suction Cath.

How do I dispose of UMIYA Suction Cath?Arrow

Dispose of the used UMIYA Suction Cath according to your local regulations. It may be appropriate to discard it as biohazardous waste.

What if I am unsure how to use the suction cath?Arrow

If you are unsure about using the suction cath, always consult a healthcare professional for medical advice or instruction.

What are the different types of UMIYA Suction Catheters?Arrow

UMIYA Suction Cath comes in various sizes and types, such as open-tip and whistle-tip catheters. The choice of type depends on the patient's needs.

How do I know when suctioning is necessary?Arrow

Signs indicating the need for suctioning include visible or audible secretions, difficulty breathing, or a drop in oxygen levels.

Can UMIYA Suction Cath be used on newborns?Arrow

Yes, UMIYA Suction Cath can be used on newborns, but with care and the appropriate size catheter. Consult a healthcare provider.

Are there other brands similar to UMIYA Suction Cath?Arrow

Yes, there are several other brands in the market that offer suction catheters. Consult with a healthcare provider to determine the best option for specific needs.

References

Book Icon

FDA De Novo Classification Request for UMIYA Suction Catheter. While not a detailed breakdown of ingredients, it confirms FDA review and clearance.

default alt
Book Icon

PubMed Central - Search for articles related to suction catheters and biocompatible materials used in medical devices. While not specific to UMIYA, research on similar devices will provide insights.

default alt
Book Icon

ISO standards related to medical devices - Search ISO standards pertaining to suction catheters, biocompatibility, and material testing for medical devices.

default alt
Book Icon

ASTM standards related to medical devices - Search ASTM standards pertaining to suction catheters, biocompatibility, and material testing for medical devices.

default alt

Ratings & Review

Very good medkart and pharmacy and good discount for medicine

ASHOK MAKWANA

Reviewed on 14-02-2024

Start FilledStart FilledStart FilledStart FilledStart Filled

(5/5)

Pharmacy of generic medicines all products in generic medicines available in very low price. Thank you medkart 😊

Rosekeyu Patel

Reviewed on 11-01-2024

Start FilledStart FilledStart FilledStart FilledStart Filled

(5/5)

Reliable and accessible pharmacy. Courteous and helpful people.

Jigar Jani

Reviewed on 29-08-2023

Start FilledStart FilledStart FilledStart FilledStart Filled

(5/5)

Good and cost effective medicines

Vishal Chaudhari

Reviewed on 15-02-2024

Start FilledStart FilledStart FilledStart FilledStart Filled

(5/5)

Very good place for medicine allmost all the medicine are available at discounted rate.

Sachin Dodhiwala

Reviewed on 10-03-2024

Start FilledStart FilledStart FilledStart FilledStart Filled

(5/5)


Marketer / Manufacturer Details

SURGICAL

Country of Origin -

India

report-us

Issue with Content?

Report Us

Customer Also Bought

UMIYA SUCTION CATH

UMIYA SUCTION CATH

MRP

80

₹64

20 % OFF

Download medkart app

Download Our App!

Get exclusive app only offers on our mobile application

Download from Google playDownload from App Store

Quick Links

default alt
default alt
default alt
default alt
default alt
default alt
default alt
default alt
default alt
default alt
default alt
default alt
default alt
default alt

Related Blogs

default alt

Balanitis Treatment: Medications, Antibiotics, and Creams

Cure inflammation of the glans penis with effective balanitis treatment. Discover best antibiotics, creams, and medications for relief.

Read More

default alt

Best Creams for fungal infection in private area - Buy Cream Online

Wondering which are the Best Creams for fungal infection in private area? Buy Fungal Infection Creams Online at affordable range.

Read More

default alt

How to Identify Generic Medicine? Find Generic Medicine

How to Identify Generic Medicine? Know in detail how to find generic medicine? Also, check how to find generic medicine for branded medicine.

Read More

default alt

High ESR Treatment: Causes and Effective Treatment Options

Learn about erythrocyte sedimentation rate (ESR), its normal range, high ESR symptoms, causes, and treatment. Understand the importance of ESR blood tests and management of ESR levels.

Read More

default alt

How to Increase Breast Size Naturally? - Breast Size Increase

Discover effective ways to naturally enhance your breast size. Explore top methods and exercises to increase breast size.

Read More

default alt

Ayurvedic Medicine for HIV: Ayurvedic Treatment for HIV

Ayurvedic Medicine for HIV: Know if there is any Ayurvedic treatment available for HIV? Know ayurvedic treatment for hiv in Detail,.

Read More

default alt

MD का फुल फॉर्म मेडिकल में फॉर्म क्या है? MD Full Form in Hindi

मेडिकल में MD का पूरा नाम डॉक्टर ऑफ मेडिसिन है। जानें MD फुल फॉर्म मेडिकल शब्दावली में। अधिक जानकारी के लिए पढ़ें।

Read More

default alt

Normal Blood Sugar Levels Chart: Sugar Level Chart

Normal Blood Sugar Levels Chart: Discover the ideal blood sugar levels by age and gain a detailed understanding of the Sugar Level Chart

Read More

default alt

टाइफाइड का इलाज: दवा, सावधानी, और उपाय - सम्पूर्ण जानकारी

Typhoid Treatment in Hindi - टाइफाइड बुखार साल्मोनेला टाइफी जीवाणु के कारण होता है। जाँचें टाइफाइड बुखार का इलाज क्या है?

Read More

default alt

Fascinating Benefits and Uses of Basil Seeds - Medkart Pharmacy Blogs

Amazing Benefits of Basil Seeds, from boosting digestion to improving skin health. Learn how to use them in your diet for maximum wellness.

Read More

Disclaimer

Medkart's sole intention is to ensure that its consumers get information that is expert-reviewed, accurate and trustworthy. However, the information contained herein should NOT be used as a substitute for the advice of a qualified physician. The information provided here is for informational purposes only. This may not cover everything about particular health conditions, medicines, generic alternatives, all possible side effects, drug interactions, warnings, alerts, lab tests, etc. Please consult your doctor and discuss all your queries related to any disease or medicine. We intend to support, not replace, the doctor-patient relationship.

India's most trusted generic medicine pharmacy.

10 Lakh+

Happy customers

35000+

Pin-codes Covered

75 Lakh+

Orders Delivered

WHO GMP Logo

Authentic Products

All WHO-GMP Certified Medicines

About Medkart Pharmacy

Our Services

Browse by

Policies

Download the app for free

Download from Google playDownload from App Store

©2025 Medkart Pharmacy. All Rights Reserved